Observations from real field work: metal lids, moisture, and low profile antennas and how manhole antenna frequency behaves underground.
Introduction
Most discussions about underground IoT eventually come back to one practical question:
how does manhole antenna frequency behave when the lid closes?

The last few weeks we’ve been involved in several projects where customers were choosing between 4G, NB-IoT and LoRa for manhole and drainage sensors.
I didn’t intend to write a long record, but each test ended up teaching something, and after a while the notes piled up.
Different frequency bands react very differently underground, especially when the antenna is low profile and installed just a few millimeters below a cast-iron lid.
These notes are simply what we observed on site, but not theory, not simulation, just field work.
Related external reference: NB-IoT overview by sciencedirect
The first site set the tone for the entire month.
A typical cast-iron manhole cover, around 35-40 cm deep.
Dry ground, moderate weather, nothing unusual.
We placed the device inside, put the lid back, and the measurement dropped by about 25-30 dB immediately.
The number wasn’t surprising ,cast iron is a reliable RF killer, but every time you see that drop in real time, it still feels more dramatic than the theory suggests.
We brought several test antennas with us that day — including the two low-profile units we’ve been refining for underground work, PIN30 and PIN120.


PIN30 is the slightly one.
PIN120 is almost flat, designed for installations where the device barely has space between the electronics and the lid.
We started the test with PIN120 because the cavity was very tight.
The moment the lid closed, the expected 25-30 dB drop appeared.
PIN120 still held NB-IoT reliably, which was exactly why this model exists , ultra-thin antennas are not supposed to perform miracles; they’re supposed to remain functional when everything is against them.
When we switched to PIN30, the numbers improved a little, not dramatically, but enough that you can “feel” the extra height giving the radiator a bit more breathing room.
Still underground, still near metal, but slightly more margin.
LoRa 868 MHz worked as well in both antenna, but the pattern was already obvious:
when the device pointed toward the street, the link margin looked healthy; when rotated 90 degrees, RSSI weakened by roughly 8-12 dB.
Seems in the underground spaces amplify directional effects.
Then 4G Cat1.
Good signal with the lid open.
But once the cover was closed, the modem connected, attempted to send data, and then gave up.
At 1.8-2.1 GHz, the combination of metal + depth is simply too much.
You can almost imagine the RF waves crashing into the lid like a high-speed insect hitting a glass window.
That first site already hinted that this month would be a reminder that “underground” never behaves like the surface.
This test already started outlining the PIN30 / PIN120 rule we’ve observed repeatedly:
PIN120 fits where nothing else fits; PIN30 performs better when space allows.
Not a marketing sentence, just how they behave in real pits.
A deeper pit a few days later added a little moisture and the same story.
This one was closer to 60 cm deep.
The walls felt damp when we touched them, rain from the night before had seeped through the concrete, leaving a thin layer of moisture.
Again, NB-IoT didn’t care.
RSRP stayed in the -108 to -115 dBm region.
It’s not fast, but it’s steady.
Steady is exactly what underground sensors want.
LoRa lost maybe 2-4 dB compared to the first site.
Possibly the moisture; possibly the cavity size; possibly both.
Nothing alarming.
4G, once again, did not survive the lid.
It connected with the lid off and disconnected as soon as we closed it.
We repeated it several times; result unchanged.
It was a polite way of the site telling us what was possible and what was not.
At this point my notebook already had a line that said:
“No 4G under metal unless the depth is shallow or the lid is composite/plastic.”
This is exactly the kind of situation where PIN120 is the only viable option.
Anything taller gets crushed or detuned beyond comfort.
One LoRa case gave us an interesting directional puzzle.
This was a different location, with a gateway only across the road — maybe 15–20 meters.
Close enough that you’d expect stable coverage from any orientation.
But when we tested it:
One direction →good
the opposite direction → 8-10 dB down.
Lifting the antenna slightly improved it again.
If someone had shown me these measurements without context, I might have guessed they were from an indoor corridor, not a manhole.
That’s how much geometry and reflections influence LoRa underground.
When people ask why we spend so much time checking device orientation, this is why.
In confined underground cavities, the antenna sees the world through narrow corridors of usable propagation, and a small angle decides everything.
Meanwhile, a non-underground test reminded us why 2.4G plays by its own rules.
Around the same time, a Swedish customer contacted us about a BLE antenna inside a lamp unit.
The lamp’s metal frame and plastic housing created a small Faraday theatre inside.
He wrote messages like:
“Z is referenced from the ground plane…
the strip has the ground plane on the connector side…
is that correct?”
The grammar wasn’t perfect, but the technical intention was crystal clear.
He wanted to match our orientation exactly, because even a small mismatch would invalidate his internal comparison.
So we tested three orientations:
-
pointing upward
-
lying flat
-
sideways along the frame
Inside the lamp, the difference was large ,15-22 dB across orientations.
No tuning change, no hardware difference.
Just the frame interacting differently with the field.
He wasn’t surprised when he saw the plots.
We weren’t either.
But it’s always satisfying when a customer’s intuition aligns perfectly with measurements.
He said, “Thanks for the patience,” which in engineering language usually means:
“You’ve passed my test. I trust you now.”
This is how long-term customers start.
By the third week, the patterns were repeating clearly.
Metal lids are always harsher than people imagine.
No amount of simulation smooths out their appetite for signal.
NB-IoT consistently showed the most resilience.
We sometimes forget that NB-IoT’s enormous link budget is not a theoretical number, in underground tests, it becomes very real.
LoRa is good too, but you need a well-placed gateway.
When LoRa fails, it rarely fails by a lot, usually it’s a borderline case caused by orientation or tunnel-like reflections.
4G almost never survives a fully closed metal lid unless the depth is very small or the lid material is non-metallic.
Nothing wrong with the protocol; it’s just not designed for this environment.
Another thing we saw repeatedly:
Thin antennas detune fast near metal.
Many underground devices require 4-6 mm antenna profiles, which means the radiator is always close to the housing.
When we moved certain antennas 3-4 mm closer to the lid, VSWR went from around 1.8 to roughly 2.6-2.8.
Not a catastrophic shift, but enough to change how the device behaves.
These results are not “data,” just observations — but they repeat enough to form reliable intuition.
So if someone asks: “Which technology should we choose?”
My answer has become simpler over time, although the reasoning behind it has not.
If the cover is metal, and the device must last years on battery → NB-IoT first.
It’s the most forgiving and the most predictable underground.
If the city already has a LoRa network, or the project requires private control → LoRa is completely valid.
Just spend time checking the worst-case angle and placement.
If the sensor needs to send large payloads or requires an always-on link → 4G, but not in deep pits with metal lids.
If the environment is unknown, or the customer is unsure →
Test NB-IoT in the worst spot first.
A single bad hole teaches more than an entire spec sheet.
Underground is never purely technical.
It’s partly material science, partly geometry, partly moisture, and partly intuition built from many tests like these.
The more we work on these projects, the clearer it becomes:
RF underground doesn’t behave like RF above ground.
And that’s exactly why field notes still matter.